Skip to main content

An extensive range of microbiological testing

ALS provide a range of microbiological testing and support services to ensure raw materials, finished products, medical devices and production environments are appropriately monitored for microbiological contamination.


With our dedicated GMP compliant laboratories, highly experienced staff, and extensive range of microbiological tests, ALS is able to provide cost-effective quality assurance. Many ALS laboratories offer both analytical and microbiological testing under one roof offering simplified Quality Control solutions.

Testes_microbiológicos

ALS: Your partner & collaborator

ALS offers quality focused testing and proactively seeks to form long-term, mutually beneficial relationships. Our clients are accustomed to receiving high-quality data, technical support and open communication. The collaborative approach is underpinned by project and client managers, skilled and qualified client service teams, access to technical experts and a management team committed to service delivery. Performing efficiently & ethically, is ready to support the healthcare industries with trustworthy and reliable QC services.

lab scientists

Non-sterile Product Testing

Testing is supported in line with the harmonized compendial requirements for the Microbiological Examination Of Non-sterile Products and the Tests for Specified Microorganisms, typically by the Membrane Filtration or Plate-count methods. ALS performs method suitability assessments of the selected test methods, demonstrating recovery of micro-organisms in the presence of product, ahead of routine testing.

ALS routinely handles a broad range of sample matrices, including harsher antibiotics, API’s, disinfectants and preservative-laden aqueous formulations, which can necessitate neutralisation for the removal of antimicrobial activity paralleled to scientific demonstration of absent neutralizer toxicity. The suitability of the counting method must be demonstrated in the presence of product.

All ALS facilities strive to achieve industry best practice inclusive of recommendations set out in USP Chapter <1117> amongst others. While not exhaustive, Compendia acceptance criteria for the microbiological quality of non-sterile dosage forms is principally defined by the route of administration backed by risk-based impact assessments as referenced in USP <1111>. The need for additional controls of objectionable microorganisms should be determined for each product. Alternative criteria is applicable to drug substances, herbal medicines and dietary supplements although in any case, typical requirements include:

Microbial Enumeration Tests
  • Total Aerobic Microbial Count (TAMC)
  • Total combined yeasts and molds count (TYMC)
Specified Micro-organisms
  • Staphylococcus aureus
  • Pseudomonas aeruginosa
  • Escherichia coli
  • Salmonella
  • Candida albicans
  • Bile-tolerant Gram-negative bacteria (BTGN)
  • Clostridia
  • Burkholderia cepacia (BCC)

Whilst compendia are harmonized for most non-sterile dosage forms, testing is conducted in accordance with:

  • USP ⟨61⟩ Microbiological Examination of Nonsterile Products: Microbial Enumeration Tests
  • USP ⟨62⟩ Microbiological Examination of Nonsterile Products: Tests for Specified Microorganisms
  • Ph. Eur. method 2.6.13 Microbiological Examination of Non-sterile Products
  • Ph. Eur. method 2.6.12 Microbial Enumeration Tests

ALS can include further specified and objectionable microorganisms into testing regimes, such as isolates from environmental monitoring, where known risks persist.

Other test methods, including rapid microbiological methods, may be used for product testing, but will require validation to demonstrate their suitability and equivalence to the compendial methods. As Technical Projects, ALS can support the development and validation of alternative procedures.

Water Activity Determinations can be supported per USP <922> and Ph. Eur. 2.9.39 methods.

Environmental Monitoring 

Effective microbiological monitoring programmes support overall microbiological control within manufacturing facilities. In the case of aseptic processing, monitoring of cleanrooms RABS (Restricted Access Barrier Systems), and isolators typically includes compressed gases, surfaces, air, and any other materials and equipment that might produce a risk of contamination. Mandatory requirements are set for aseptic processing per USP ⟨1116⟩

Microbiological monitoring and control programs for non-sterile manufacturing are not yet as well defined by compendia or regulatory guidelines. In a similar vein to aseptic, the extent of monitoring depends upon the manufacturing activity although tends be driven by circumstance-specific risk assessments with sampling and testing proportional to supply chain risk. Sound scientific rationale is naturally expected and trend analysis of the generated data helps underpin understanding and effectiveness.

ALS offers a complete range of supportive testing for both Sterile and non-Sterile environmental monitoring programmes, including:

Incubation, enumeration and reporting of:

  • Active Air Plates and strips
  • Impacted Compressed Gas (supporting ISO 8573 requirements)
  • Contact Plates
  • Glove Prints (Finger Dabs)
  • Settle Plates (Passive Air Monitoring)

Inoculation of blank control plates for Growth Promotion / Fertility testing.

Water Testing (Performance qualification and routine monitoring)

  • Potable Feed
  • Purified Waters (Bulk and in Containers)
  • Product used
  • Water used in washing process
  • Steam

Surface Monitoring

  • Swabs
  • Contact Plates
  • Drains

In addition to testing, ALS’ offers consultancy services and are proactive in supporting:

  • Company-wide education of Environmental Monitoring programmes and their application
  • The design and evaluation of Microbiological Monitoring Programmes
  • Risk assessments
  • Technique Training and Establishment (e.g. culture media selection, incubation condition selection, and sampling best practices)
  • The validation of monitoring techniques
  • Performance qualification and monitoring thereafter
  • Acceptance Criteria Establishment and Limit Setting (Non-Sterile Environments)
  • Investigations and root cause analysis

Container Closure Integrity Testing

Container Closure Integrity Testing (CCIT) is an assay that evaluates the adequacy of container closure systems to maintain a sterile barrier against potential contaminants. Contaminants that could potentially cross a container closure barrier include microorganism, reactive gases, and other substances (USP <1207>). Container closure systems should maintain the sterility and product quality of sterile final pharmaceutical, biological, and vaccine products throughout their shelf-life (Ewan, S. et al., 2015).

Based on the drug formulation (e.g. liquid or lyophilized) and the type of the container (e.g. bottle, vial, ampule and syringe etc.) various methods can be employed to perform the container closure.

Non-destructive
  • Electrical Conductivity and Capacitance Test (HVLD)
  • Laser-based Gas Headspace Analysis
Destructive
  • Blue Dye Ingres Leak Test
  • Microbial Immersion Testing

Various CCIT techniques can be supported between ALS and our partners NUVISAN.

Particulate Testing

ALS can support particulate testing alongside microbiological testing of sterile drug products. Particulate contamination of injections and infusions consists of extraneous, mobile undissolved particles unintentionally present in the solutions. It is considered a critical risk with quality control testing commonplace throughout in-process controls and a mandatory testing requirement in release testing specifications. Particulate Contamination is predominately split into two forms: Visible and Sub-Visible. ALS commonly supports the following compendia in connection with the practical application of industry best practices:

  • Ph. Eur. 2.9.20 Appendix XIII B. Particulate Contamination: Visible Particles / USP ⟨790⟩ Visible Particulates in Injections
  • Ph. Eur. 2.9.19 Method I / USP General Chapter 788: Light Obscuration Particle Count Test
  • Ph. Eur. 2.9.19 Method 2 / USP General Chapter 788: Microscopic Particle Count Test